Design principle
Flow chart :
Raw water → raw water tank →raw water pump →Mechanical filter → A/c filter →10μ Precise filter (5μ guard filter)→High pres.pump →RO device →Pure water tank →Pure water pump→UV Sterilizer→0.22μm Ti.filter → Using water point
Reverse osmosis running condition
1) output: 10 m3/(h.set)(25℃)
2) water recycle rate: 70%
3) desalination rate: ≥97%
4) primary pressure value after using 3 years:0.13 M Pa
5) in-feeding water condition:
a)temperature: 25℃
b)Pressure: 1.0-1.5MPa
c) SDI: ≤4
d) Residual chlorine
: <0.1mg/L
e) PH : 3-10
f) COD Mn : ≤2 mg/L
g) Fe : <0.05 mg/L