≥1 piece |
Application:
Output temperature is below 16 degree, dew point td is below -60 degree. Be used for liquid injection room, baking room and formation room with special require etc,enable these workshops to achieve 20-24degree, RH below 1%,also can adjust air temperature and humidity according to the actual requirements.
Principle:
Device is a combined type , which has functions of air filtering, cooling dehumidification, rotor dehumidification, air supply and temperature adjustment, etc.When fresh air go through the filter ,enter into and contact fully with the surface cooler , due to the surface temperature below the air dew point temperature, air cooled,at the same time, the included water turning into condensed water separated out, then the air temperature and humidity decrease, the low temperature and humidity air dehumidified by the first rotor mixing return air of the drying room, and enter into the second rotor for further dehumidification, then we get the dry air, after tempering, sent it to the dry room to meet the technological requirements.
desiccant rotor is the key part of dehumidifier device, which take high aluminum fiber honeycomb material as the carrier, and the super silica gel or molecular sieve as moisture absorption material. Honeycomb material has huge surface area ,more than
Character:
1. Consist of the fresh air filter, secondary silicone or molecular sieve rotor, fresh air surface cooler, return air surface cooler, fan, return air filter (tempering section and regeneration parts.
2. Regeneration heating by stainless steel tube electric heater or by copper tube aluminum fin steam heater.
3. Efficient centrifugal fans, high-strength structural framework, high-pressure foam double-sided enclosure, anti-cold bridge treatment.
4. PLC control, electric multi-protection, operation safety, stable and reliable.
Parameter Model |
Processing Air |
Regeneration Air |
Regeneration Mode |
Outlet Air |
Drive rotor power kW |
Installed power |
Regen Steam capacity Kg/h |
Overall Dimantion |
Weight |
Support facilities’cooling capacitykW |
Cooling water consm t/h |
|||||||
Air flow m3/h |
Fan power kW |
Air flow m3/h |
Fan power kW |
Primary rotor power kW |
Second Rotor power kW |
T °C |
Dew point Tem °C |
Electric Heat kW |
Steam Heat kW |
Length mm |
Width mm |
Height mm |
||||||
ZHL-D(Z) |
1000 |
2.2 |
250 |
0.55 |
1.5 |
7.2 |
≤16 |
≤-60 |
0.1 |
11.45 |
2.75 |
14.5 |
5400 |
980 |
1630 |
1500 |
15.9 |
2.7 |
ZHL-D(Z) |
1500 |
0.5 |
375 |
0.75 |
2.4 |
10.8 |
0.1 |
16.15 |
2.95 |
22.0 |
5400 |
1080 |
1730 |
1600 |
23.9 |
4.1 |
||
ZHL-D(Z) |
2000 |
3 |
500 |
0.75 |
3.6 |
14.4 |
0.13 |
21.75 |
3.75 |
30.0 |
5800 |
1180 |
1830 |
1700 |
31.8 |
5.5 |
||
ZHL-D(Z) |
2500 |
3 |
625 |
0.75 |
4 |
18 |
0.16 |
25.75 |
3.75 |
36.7 |
5800 |
1230 |
1980 |
1900 |
39.8 |
6.8 |
||
ZHL-D(Z) |
3000 |
3 |
752 |
1.1 |
4.8 |
21.6 |
0.16 |
30.5 |
4.1 |
44.0 |
5800 |
1330 |
1980 |
2200 |
47.8 |
8.2 |
Note:1.parameter of french air:
2. The ratio of fresh air is 10% of air output.
3. Residual pressure air supply above 600Pa
4. Supporting facilities’ cooling volume and frozen water consumption, you can choose one of them.
5. Using the user original freezing system or configuring chilled water system individually, please point out when ordering.