Magnetic Flow Meter Water Flow Meter Mag Liquid Food Sanitary Flowmeter
Product Feature
1 .Virtually No Pressure Loss
There is no moving part to down the pressure.
2.Corrosion protection, abrasion resistant
3. High accuracy, Stable performance
The struction is test strictly to ensure the high accuracy and stability
4.High level of anti-vibration and anti-jamming, wide measuring dimensions
polyurethane was injected to the sensor body to ensure the sensor has good capability
5.Multi-Output Interface4~20mA, Pulse, Alarm Outputs, RS-485 and Modbus Communication
Technical data
| 1 | Nominal Meter size | 3 to 3000 mm |
| 2 | LIiquid Pressure(MPa) | ANSI CL150,JIS,GB(can reach to 42MPa) |
| 3 | Accuracy | ±0.5%, ±1% (upon req.) |
| 4 | Minimum Conductivity | 5μs/cm |
| 5 | Fluid Temperature | -25 to 60(-13 to 149),-25 to 140(-13 to 284) |
| 6 | Electrode Material | SST 316L (standard), Hastelloy, Tantalum, Titanium,TungstenCarbide (upon req.) |
| 7 | Liner Material | CR, FEP, PTFE, PFA |
| 8 | Relative Humidity | ≤85% |
| 9 | Ambient Temperature | -30 to 60 (-22 to 140) |
| 10 | Current Output | 0 to 10mA or 4 to 20mA |
| 11 | Frequency Output | 0 to 5000Hz with photoelectric isolation |
| 12 | Pulse Output | Adjustable from 0.001 to 1000 Ltr/Pulse |
| 13 | Alarm Output | Upper Alarm-ALMH,Lower Alarm-ALML with photoelectric isolation |
| 14 | Communications | RS-485 with galvanic isolation, MODBUS, RS-232 without galvanic isolation |
| 15 | Supply Power | 85 to 250VAC (45 to 63Hz) 16 to 36VDC |
| 16 | Power | S10W/AC, S7.5W/DC |
Product Details
Summary
An electromagnetic flowmeter is composed of two parts- electromagnetic flow sensor and electromagnetic flow transducer.
The operation of an electromagnetic flowmeter is based on Faraday law of electromagnetic induction.The mainly parts of the sensor are: measuring tube,electrode poles,excitation coil,iron core,yoke and housing. The measuring tube of the sensor is a short alloy tube whose diameter is D, the inner suface of it has an insulating liner.Two electrodes are fixed in the measuring tube along with the diameter direction of it and they usually flush with the inner surface liner.When excitation coil pulsed by two-way square wave,there generates a working magnetic field with a flux density B in the vertical direction of the measurement axis.In the meantime,if some electrical conductivity liquid flows at an average velocity V through the measuring tube ,cuts lines of the magnetic field,there generates induced electromotive force E.Electromotive force E is directly proportional to the product of flux density B,measuring tube diameter D and average velocity V,that's: E BVD. Electromotive force E(flow signal) is measured by the electrodes and transmitted to transducer through cable.After the transducer handles the flow signal by magnifying it, the flow and total amount can be displayed,also will output pulse and analog current etc. The transducer of LDG type electromagnetic flowmeter has an intelligent indicator suggesting Chinese characters LCD display.
| Place of Origin: |
Shanghai China (Mainland)
|
Brand Name: |
ANJUN
|
Model Number: |
AMF-50-106-0000-F0A
|
| DN: |
3-3000mm
|
Lining material: |
Chloroprene rubber,Polyurethane rubber,PTFE,PFA,FEP
|
Electrode material: |
316L,Hb,Hc,Ti,Ta,Pt...
|
| Wroking pressure: |
DIN PN0.6-42MPa,ANSI CL150-2500,JIS 10-30K
|
Working temperature: |
Maximum can up to 260℃
|
Signal output: |
4-20mA,Pulse,Frequency output
|
| Communication: |
RS485,RS232,HART,MODBUS,PROFIBUS,GPRS
|
Power supply: |
220VAC,24VDC,Lithium battery
|
Accuracy: |
0.5%,0.2%
|
| Material: |
Carbon steel,304SS,316SS,316LSS
|