≥1 piece |
Application:
Output temperature is below 18 degree, dew point td is below -8 degree. Be used for mixing workshop, coating workshop, production workshop, assembling workshop, etc, enable environmental index of these workshops to achieve 20-24degree, RH below 20%.
Principle:
Device is a combined type , which has functions of air filtering, cooling dehumidification, rotor dehumidification, air supply and temperature adjustment, etc.When fresh air go through the filter ,enter into and contact fully with the surface cooler , due to the surface temperature below the air dew point temperature, air cooled ??? at the same time, the included water turning into condensed water separated out, then the air temperature and humidity decrease, the low temperature and humidity air mixing return air of the drying room, after tempering by return air surface cooler ,enter into the desiccant rotor for further dehumidification. At last, after tempering, we get the dry air, which is sent to dry room to meet the technological requirements.
Character:
1. Consist of the fresh air filter, fresh air surface cooler, return air filter, former surface cooler, and super silicone rotor section, tempering section and regeneration parts.
2. Regeneration heating by stainless steel tube electric heater or by copper tube aluminum fin steam heater.
3. Efficient centrifugal fans, high-strength structural framework, high-pressure foam double-sided enclosure, anti-cold bridge treatment.
4. PLC control, electric multi-protection, operation safety, stable and reliable.
Parameter Model |
Processing Air |
Regeneration Air |
Regeneration Mode |
Outlet Air |
Drive rotor power kW |
Installed power |
Overall Dimantion |
Weight |
Support facilities' cooling capacity kW |
Cooling water consum t/h |
|||||||
Air flow m3/h |
Fan power kW |
Air flow m3/h |
Fan power kW |
Electric power kW |
Steam consum kg/h |
T °C |
Dew point Tem°C |
Electric Heating kW |
Steam Heating kW |
Length mm |
Width mm |
Height mm |
|||||
ZLB-D(Z) |
1000 |
0.0 |
340 |
1.1 |
8.4 |
14 |
≤16 |
≤-8 |
0.06 |
9.56 |
1.16 |
5000 |
800 |
1800 |
1200 |
7.9 |
1.4 |
ZLB-D(Z) |
1500 |
1.5 |
500 |
1.1 |
14.4 |
24 |
0.06 |
17.06 |
2.66 |
5000 |
850 |
1850 |
1250 |
11.9 |
2 |
||
ZLB-D(Z) |
2000 |
2.2 |
660 |
1.1 |
18 |
30 |
0.06 |
21.36 |
3.36 |
5250 |
900 |
1900 |
1300 |
15.8 |
2.7 |
||
ZLB-D(Z) |
2500 |
3 |
850 |
0.0 |
21.6 |
36 |
0.09 |
24.69 |
3.09 |
5250 |
950 |
2000 |
1350 |
19.8 |
3.4 |
||
ZLB-D(Z) |
4000 |
4 |
135 |
2.2 |
30 |
50 |
0.12 |
36.32 |
6.32 |
5250 |
1180 |
2200 |
1600 |
31.6 |
5.4 |
||
ZLB-D(Z) |
5000 |
4 |
1650 |
2.2 |
36 |
60 |
0.12 |
42.32 |
6.32 |
5700 |
1230 |
2300 |
1800 |
39.5 |
6.8 |
||
ZLB-D(Z) |
6000 |
0.0 |
2000 |
0.0 |
42 |
70 |
0.12 |
42.12 |
0.12 |
5700 |
1330 |
2400 |
2000 |
47.4 |
8.2 |
||
ZLB-D(Z) |
8000 |
0.0 |
2350 |
3 |
66 |
110 |
0.12 |
69.12 |
3.12 |
5850 |
1430 |
2500 |
2200 |
63.2 |
10.9 |
||
ZLB-D(Z) |
10000 |
0.0 |
3450 |
3 |
84 |
140 |
0.18 |
87.18 |
3.18 |
6000 |
1630 |
2650 |
2400 |
79.0 |
13.6 |
||
ZLB-D(Z) |
12000 |
11 |
4000 |
3 |
102 |
170 |
0.18 |
116.2 |
14.18 |
6300 |
1730 |
2800 |
2600 |
94.8 |
16.3 |
||
ZLB-D(Z) |
15000 |
11 |
5000 |
5.5 |
120 |
200 |
0.25 |
136.8 |
16.75 |
6300 |
1930 |
3000 |
2800 |
118.5 |
20.4 |
||
ZLB-D(Z) |
20000 |
15 |
6600 |
0.0 |
156 |
260 |
0.25 |
176.8 |
15.25 |
6750 |
2180 |
3200 |
3000 |
158.0 |
27.2 |
Note: 1.parameter of french air:
2. The ratio of fresh air is 10% of air output.
3. Residual pressure air supply≥600Pa
4. Supporting facilities’ cooling volume and frozen water consumption, you can choose one of them.
5. Using the user original freezing system or configuring chilled water system individually, please point out when ordering.