FGA-4100(4G)  FGA-4100(5G)  automotive gas analyzer,gasoline and diesel gas analyzer,digital gas detector

 It is designed for Environmental Protection Departments, Auto and Motorcycle Manufacturers, Auto-repair Enterprises, Police and Traffic Test Stations and scientific Research Departments to test auto emission during repairing, inspecting and examining on road testing and science research.

Main Parameter

 

Model

 FGA-4100(4G)

 FGA-4100(5G)

 Measure 

range

 HC

 (0~10.000)X10-6 vol

 (0~10.000)X10-6 vol

 

 CO

 (0~10)X10-2 vol

 (0~10)X10-2 vol 

 

 CO2

 (0~20)X10-2 vol

 (0~20)X10-2 vol

 

 O2

 (0~25)X10-2 vol

 (0~25)X10-2 vol

 

 NO

 ----------------------

 (0~5,000)X10-6 vol

 

 λ

 0.5~3.0

 

 Oil temp

 (0~150)°C 

 

 Rotated speed

 (0~10,000)r/min-1

 indication error

 

 Absolute error

Relative error

 

 HC

 ±12 X10-6vol

 ±5%

 

 CO

 ±0.06 X10-2vol

 ±5%

 

 CO2

 ±0.5 X10-2vol

 ±5%

 

 O2

 ±0.1 X10-2vol

 ±5%

 

 NO

 ±25 X10-6vol

 ±4%

 Response time

 HC/CO/CO2:≤8s;O2/NO:≤12s

Voltage 

 AC (220V±22)V;(50±1)Hz 

output

 RS-232/RS-485

weight

 9kg

dimension

 310mmX170mmX400mm

 

Measuring ranges: 

HC:(0~10000)ppm

CO:(0~10)%

CO2:(0~20)%

O2:(0~25)%
NO:(0~4000)ppm

λ:0.5~3.0

Oil temperature:(0~150)°C

Rotate speed:(250~10000)r/min

resolution:

HC:1ppm  

CO:0.01%  

CO2:0.1% 

    O2:0.1%

NO:1ppm 

oil term:0.1°C

rotate speed:1rpm


 *Response time: HC/CO/CO2: within 10s, O2/NO: within 15s
 *Warm-up time: 15min.
 *Power: AC220V±10%,50Hz±1%
 *Output port: RS-232C
 *Power consumption: 50W
 *Weight:  8kg
 *Dimension: 310mm×170mm×400mm (W×H×D)
 *Display mode: with big LCD screen and Chinese/English menu
 *Accuracy : HC: ±12ppm vol (absolute error) or ±5% (relative error)
            CO: ±0.06% vol (absolute error) or ±5% (relative error)
            CO2: ±0.5% vol (absolute error) or ±5% (relative error)
            O2: ±0.1% vol (absolute error) or ±5% (relative error)
            NO: ±25ppm vol (absolute error) or ±4% (relative error)
 *The two/four gas analyzers can be upgraded.

 